Aufrufe
vor 2 Jahren

SP Hull LyoStar 4.0 Datenblatt EN

  • Text
  • Gefriertrockner
  • Laborkomplettausstatter
  • Bartelt
  • Laborausstatter
  • Wwwbarteltat
  • Spec
  • Lyostar
  • Hull
  • Specifications
  • Dryer
  • Recommends
  • Lowest
  • Clearance
  • Volume
  • Requirements
  • Shelves
  • Condenser
  • Vacuum
SP Hull LyoStar 4.0 Datenblatt EN

LyoStar® 4.0 Research and Development Tray Freeze Dryer Dimensional Data Shelf Configuration Dimensions Move In Dimensions Width 994 mm (39.1 in) 994 mm (39.1 in) Depth 1208.5 mm (47.6 in) 1208.5 mm (47.6 in) Height 2144.0 mm (84.4 in) 1960.1 mm (77.2 in) Number of Shelves Shelf Area Shelf Clearance 1 Shelf Latched Shelf Clearance with Shelf Latching 2 Shelves Latched 3 Shelves Latched Maximum Weight (estimated) 680 kg (1500lbs) 680 kg (1500lbs) 3 Shelves 0.427 m2 (4.6 ft2) 71.1 mm (2.8 in) 109.2 mm (4.3 in) 215.9 mm (8.5 in) - Minimum Clearance on All Sides 610 mm (24 in) - 4 Shelves 0.567 m2 (6.1 ft2) 50.8 mm (2 in) 66 mm (2.6 in) 101.6 mm (4 in) 203.2 mm (8 in) Note: SP recommends a 60 cm clearance around all sides of the unit for serviceability. If machines are placed side by side, increase the minimum clearance to 1.2 m. Electrical Requirements Voltage 208 / 230 VAC 400 VAC (5 wire) Hertz 50 Hz, 60 Hz 50 Hz Phase 1 Φ 3 Φ Breaker Amperage 40 A 30 A Workstation Electrical Requirements Voltage (VAC) 115 VAC 230 VAC Hertz 60 Hz 50 Hz Phase 1 Φ 1 Φ Shelf Size (W x L x H): 279.4 x 508 x 12.7 mm (11 x 20 x .5 in) Refrigerant Information Additional Information Construction Gas 1 Gas 2 F gas R449A R508B Charge (Kg) 1.2 0.95 GWP 1397 13396 EPA SNAP IPR IPR/VLTR Safety Class A1 A1 Total CO 2 e (t) 14.402 316L Stainless Steel Shelves, Product Chamber, Condenser Chamber and Condenser Coil Sample Extractor Electrical Requirements (For Vacuum Pump) Voltage (VAC) 115 VAC 230 VAC Hertz 60 Hz 50 Hz Phase 1 Φ 1 Φ Vial Capacity Vial Size 2R 6R 10R 20R 30R # Per Shelf 594 312 267 162 162 Total # of Vials 1,782 936 801 486 486 Vacuum Pump Stoppering Defrost Type Isolation Valve Refrigerant Type Vapor Port Diameter Noise Level Two-Stage Rotary Vane, Dry Pump Optional Bottom-Up Hydraulic Hot Gas Butterfly Valve, Pneumatic CFC-Free 101.6 mm (4 in - 3.9 in ID) Noise from the equipment under normal operating conditions shall not exceed 70-75 dBa when measured at any point 1 m away from the equipment. Based on a 3 shelf configuration (estimated) § When testing shelf temperature uniformities within a range of -40°C to 40°C, shelf temperature deviations shall not exceed the specification relative to the mean of the highest and lowest temperature readings. † The pneumatic isolation valve, a standard feature of SP Hull® LyoStar® 4.0, shall require the use of compressed air. ‡ SP recommends an O2 sensor to monitor that the oxygen concentration in the room does not drop below acceptable levels. Lyophilizers equipped with ControLyo® shall exceed the specified noise level rating for approximately 3 to 5 seconds during de-pressurization. SP recommends the use of both hearing and eye protection during the ControLyo® process. © 2021 SP Industries, Inc. SP reserves the right to change specifications without notice. All trademarks referenced in this document are registered or common law trademarks of SP Industries, Inc. or its affiliates in the U.S. and/or other countries. *Other specific brand or product names may be registered trademarks of their respective companies. Part Number 100024466 Rev 003, Jul 21 935 Mearns Rd, Warminster, PA 18974 | scientificproducts.com International +1 215-672-7800 | US Toll Free 800-523-2327 | hello@spindustries.com

News & Aktionen

Broschüren/Kataloge