PIPETMAN® M SINGLE CHANNEL Gilson Specifications ISO 8655-2 Model PIPETMAN DIAMOND Tips Part Number Standard PIPET mode Volume Range Volume (μL) Systematic error (μL) Random error (μL) REPETITIVE mode volume Systematic error (µL) Random error (µL) P10M D10 DL10 DF10ST DFL10ST F81022 0.5–10 µL P20M D200 DF30ST F81023 2–20 µL P100M D200 DF100ST F81013 5–100 µL 0.5 1 5 10 2 10 20 5 10 50 100 ± 0.040 ± 0.025 ± 0.060 ± 0.080 ± 0.075 ± 0.100 ± 0.150 ± 0.35 ± 0.30 ± 0.38 ± 0.40 ≤ 0.013 ≤ 0.012 ≤ 0.020 ≤ 0.025 ≤ 0.025 ≤ 0.035 ≤ 0.050 ≤ 0.10 ≤ 0.10 ≤ 0.12 ≤ 0.15 0.5–10 µL 2–20 µL 5–100 µL ± 0.12 ± 0.12 ± 0.12 ± 0.12 ± 0.2 ± 0.2 ± 0.2 ± 0.2 ± 0.8 ± 0.8 ± 0.8 ± 0.8 ≤ 0.08 ≤ 0.08 ≤ 0.08 ≤ 0.08 ≤ 0.1 ≤ 0.1 ≤ 0.1 ≤ 0.1 ≤ 0.3 ≤ 0.3 ≤ 0.3 ≤ 0.3 P200M D200 D300 DF200ST DF300ST F81024 20–200 µL 20 100 200 ± 0.40 ± 0.80 ± 1.00 ≤ 0.15 ≤ 0.22 ≤ 0.26 5–200 µL ± 1.6 ± 1.6 ± 1.6 ≤ 0.6 ≤ 0.6 ≤ 0.6 P300M P1200M D200 D300 D1000 D1200 DF200ST DF300ST F81014 20–300 µL 20 30 150 300 100 DF1000ST DF1200ST F81015 100–1200 µL 120 600 1200 ± 0.80 ± 0.70 ± 0.90 ± 1.05 ± 2.5 ± 2.4 ± 3.6 ± 6.0 ≤ 0.16 ≤ 0.20 ≤ 0.23 ≤ 0.30 ≤ 0.4 ≤ 0.4 ≤ 0.8 ≤ 1.2 10–300 µL 20–1200 µL ± 4.0 ± 4.0 ± 4.0 ± 4.0 ± 16 ± 16 ± 16 ± 16 ≤ 1.5 ≤ 1.5 ≤ 1.5 ≤ 1.5 ≤ 6.0 ≤ 6.0 ≤ 6.0 ≤ 6.0 P5000M D5000 F81016 500–5000 µL 500 2500 5000 ± 10 ± 15 ± 25 ≤ 2 ≤ 4 ≤ 7 100–5000 µL ± 40 ± 40 ± 40 ≤ 15.0 ≤ 15.0 ≤ 15.0 P10mLM D10mL F81017 1–10 mL 1 mL 5 mL 10 mL ± 25 ± 30 ± 50 ≤ 4 ≤ 8 ≤ 12 200 µL–10 mL ± 60 ± 60 ± 60 ≤ 30.0 ≤ 30.0 ≤ 30.0 PIPETMAN® M MULTICHANNEL P8x10M P12x10M D10 DL10 DF10ST DFL10ST F81025 F81026 0.5–10 µL 0.5 1 5 10 ± 0.05 ± 0.04 ± 0.08 ± 0.10 ≤ 0.02 ≤ 0.02 ≤ 0.04 ≤ 0.06 0.5–10 µL ± 0.24 ± 0.24 ± 0.24 ± 0.24 ≤ 0.16 ≤ 0.16 ≤ 0.16 ≤ 0.16 P8x20M P12x20M DL10 D200 DFL10ST DF30ST F81027 F81028 1–20 µL 1 2 10 20 ± 0.08 ± 0.09 ± 0.15 ± 0.25 ≤ 0.05 ≤ 0.06 ≤ 0.10 ≤ 0.12 1–20 µL ± 0.4 ± 0.4 ± 0.4 ± 0.4 ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2 P8x100M P12x100M D200 DF100ST F81018 F81019 10–100 µL 10 50 100 ± 0.25 ± 0.50 ± 0.80 ≤ 0.14 ≤ 0.20 ≤ 0.25 5–100 µL ± 1.6 ± 1.6 ± 1.6 ≤ 0.6 ≤ 0.6 ≤ 0.6 P8x200M P12x200M D200 D300 DF100ST DF200ST DF300ST F81029 F81030 20–200 µL 20 100 200 ± 0.50 ± 1.00 ± 2.00 ≤ 0.16 ≤ 0.30 ≤ 0.50 5–200 µL ± 3.2 ± 3.2 ± 3.2 ≤ 1.2 ≤ 1.2 ≤ 1.2 P8x300M P12x300M D200 D300 DF200ST DF300ST F81031 F81032 10–300 µL 10 30 150 300 ± 1.00 ± 1.00 ± 1.50 ± 2.40 ≤ 0.18 ≤ 0.18 ≤ 0.375 ≤ 0.45 10–300 µL ± 8.0 ± 8.0 ± 8.0 ± 8.0 ≤ 3.0 ≤ 3.0 ≤ 3.0 ≤ 3.0 P8x1200M P12x1200M D1200 F81020 DF1200ST F81021 50–1200 µL 50 120 600 1200 ± 4.0 ± 4.0 ± 6.0 ± 9.6 ≤ 0.7 ≤ 0.7 ≤ 1.5 ≤ 1.8 50–1200 µL ± 32 ± 32 ± 32 ± 32 ≤ 12 ≤ 12 ≤ 12 ≤ 12 Gilson maximum permissible errors are guaranteed only when PIPETMAN pipettes are used with the recommended PIPETMAN DIAMOND Tips. Under these conditions, Gilson volumetric specifications in standard pipetting (PIPET mode) are guaranteed with a performance exceeding ISO 8655-2 recommendations for this mode. In the absence of ISO recommendations for repetitive pipetting mode for air-displacement pipettes, Gilson volumetric specifications for repetitive pipetting (REPETITIVE mode) are guaranteed within ISO 8655-2 recommendations for standard pipetting (Cf. ISO 8655-2 table 1). ACCESSORIES Description PIPETMAN M Power Carrousel PIPETMAN M Stand Adaptor Part Number FB1001 F807023 Full range of pipette accessories page 28 SHOP ONLINE WWW.GILSON.COM 19
INCREASE PRODUCTIVITY WITHOUT SACRIFICING COMFORT Built for traceability and comfort, PIPETMAN® L is designed to increase daily productivity, giving you the ability to pipette longer without fatigue. This pipette combines the legendary durability of the PIPETMAN® Classic, a newly designed body, and a state-of-the-art volume-locking mechanism for precision. ALL DAY PIPETTING COMFORT Balance is key for a comfortable pipetting experience. Every aspect of the PIPETMAN L has been designed with your hand in mind to help increase daily productivity and pipette longer without fatiguing your hand. SECURE PIPETTING PIPETMAN L features a true volume‐locking mechanism that guarantees no accidental volume change during pipetting cycles, which could alter accuracy and precision. Additionally, PIPETMAN L multichannel models offer optimized performance across channels for a uniform sample delivery. PIPETMAN L is also available as a fixed volume pipette, refer to page 26. FULLY AUTOCLAVABLE* PIPETMAN L variable volume models are fully autoclavable without disassembly for maximum convenience and protection from cross-contamination. *To determine if your PIPETMAN L is autoclavable, check to see if the serial number begins with NK or newer versions. If you’re unsure, please contact your local Gilson representative. FULLY VARIABLE VOLUME MODELS AUTOCLAVABLE 20 LIQUID HANDLING
LC PURIFICATION SYSTEMS With the ca
® OLIGO PURIFICATION ISOLATE, ANAL
ACCESSORIES OPTIMIZE YOUR INSTRUMEN
GEL PERMEATION CHROMATOGRAPHY (GPC)
EXTRACTION GET THE MOST FROM YOUR A
The ASPEC® 274 System for positive
CONSISTENT PERFORMANCE, RELIABLE RE
Gilson Sup aT op SYRINGE FILTERS C
EXTRACTMAN® offers a fast and gent
SOFTWARE SOFTWARE DESIGNED BY SCIEN
Laden...
Laden...
Laden...