Aufrufe
vor 7 Jahren

Hamilton-Katalog: Spritzen und Nadeln

  • Text
  • Syringes
  • Syringe
  • Volume
  • Needles
  • Gauge
  • Plunger
  • Hamilton
  • Length
  • Luer
  • Removable
Hamilton-Katalog: Spritzen und Nadeln

CHROMATOGRAPHY AND

CHROMATOGRAPHY AND ANALYSIS SYRINGES | HPLC AUTOSAMPLER SYRINGES CTC LEAP Syringes Cemented Needle Syringes A200S P/N Volume Gauge Length Point 203560 10 µL 22s ga 51 mm 3 203566 100 µL 22s ga 51 mm 3 CTC PAL Syringes PAL LC HTC, HTS CTC PAL ® autosamplers are one of the most popular sample injection systems for HPLC analyses. Customers rely on its ability to sample from many different vial and well types and on its ultimate platform flexibility. The syringe is at the heart of every injection that the LC PAL ® system performs, and CTC chose Hamilton to provide this critical component. This section has syringes for PAL LC instruments. This section also includes syringes for Agilent, Dionex, and Waters as these instruments are a private label for CTC. S-Line Syringes S-Line syringes are the cost-effective choice for CTC PAL autosampler applications. It incorporates a precisionmachined PTFE plunger tip which creates a leak-free seal. With the tight fit in the glass barrel, the tip wipes the interior of the syringe barrel free of sample, minimizing sample carryover. C-Line Syringes C-Line syringes incorporate several unique design features that ensure superior performance. The unique flange alignment design aids in installation and results in fewer bent needles while the plunger button can be adjusted to prevent plunger tip damage. An innovative direct attachment design of the needle to the barrel minimizes sample carryover. X-Type Syringes X-Type syringes have a near zero carryover and a long-lasting plunger tip to meet the requirements of sensitive, highthroughput life science applications. The syringe glass barrel is polished and coated for chemical inertness and enhanced lifetime. The needle is deactivated and coated to reduce sample adsorption. S-Line Syringes P/N Volume Barrel (O.D.) Gauge Point 67444-01 10 µL 6.6 mm 22s ga 3 67446-01 25 µL 7.9 mm 22s ga 3 67450-01 50 µL 6.6 mm 22 ga 3 67452-01 100 µL 6.6 mm 22s ga 3 67442-01 250 µL 7.9 mm 22 ga 3 67448-01 500 µL 7.9 mm 22 ga 3 34

CHROMATOGRAPHY AND ANALYSIS SYRINGES | HPLC AUTOSAMPLER SYRINGES CTC PAL Syringes (Cont.) C-Line Syringes X-Type Syringes P/N Volume Barrel (O.D.) Gauge Point 203073* 10 µL 6.6 mm 22s ga 3 203194 10 µL 6.6 mm 22s ga 3 203274 25 µL 6.6 mm 22s ga 3 203075 25 µL 7.9 mm 22s ga 3 203077 100 µL 6.6 mm 22s ga 3 203235 100 µL 6.6 mm 22 ga 3 203079 250 µL 7.9 mm 22 ga 3 203349 500 µL 7.9 mm 22 ga 3 203081** 1 mL 7.6 mm 22 ga 3 203083** 2.5 mL 9.65 mm 22 ga 3 203085** 5 mL 13.6 mm 22 ga 3 *This syringe is a Microliter Syringe. **These syringes are a Luer Tip Cemented Needle (LTN) termination. P/N Volume Barrel (O.D.) Gauge Point 204475 25 µL 7.9 mm 22s ga 3 204379 50 µL 7.9 mm 22s ga 3 204452 100 µL 6.6 mm 22s ga 3 204400 100 µL 6.6 mm 22 ga 3 202668* 100 µL 6.6 mm * This part number is a Removable Needle (RN) termination. Dionex Gina Syringes ASI-100 Removable Needle (RN) P/N Volume 7654-01 (no needle included) 25 µL 7657-01 (no needle included) 250 µL Hitachi LaChrom Syringes L-2200, L-7200, L-7250, L-8800, L-8900, AS1000, AS2000 Special Termination P/N Volume 0160310 500 µL Point Styles Point 2 Point 3 Point 4 Point 5 Point AS 35

News & Aktionen

Broschüren/Kataloge